  1. TDSPTTU1 Aranet Sensor T/RH T: -40°C to 60°CRH: 0% to 100%  IP42 920 MHz

    Aranet Sensor T/RH T: -40°C to 60°CRH: 0% to 100% IP42 920 MHz

    $70.80

    Aranet wireless temperature and relative humidity sensors have exceptionally low energy consumption that allows the sensors to function up to 10 years without replacing the battery. Aranet Sensors are extremely durable and can be placed in an open environment as well as indoors or humid locations.
    Features
    • Sensors are compatible only with Aranet base stations • Measures: temperature (-40°C to 60°C/ -40°F to 140 °F) • Measures: Relative humidity (0% to 100%) • Line-of-Sight range: up to 3 km/ 1.9mi • Operating environment: indoor and outdoor use • Transmitter power: 14 dBm • Data Transmission: 1, 2, 5, 10 minutes • Battery life: up to 10 years • Protection class: IP42 • Dimensions: 115x44x25 mm/ 4.5×1.7×1 in
    Specifications
    • Measurements: Temperature and Relative Humidity • Line if Sight Range: 3km/1.9mi • Operating Environment: Indoor and Outdoor use • Transmit power: 14dBm • Frequency: Depends on base station instructions • Measurement Range:     Temperature: -40°C to 60°C/-40°F to 140°F     Relative Humidity: 0% to 100% • Temperature Measurement Accuracy:     -10°C to 60°C/14°F to 140°F 0.4°C/0.72°F     -20°C to -10°C/-4°F to 14°F 0.6°C/1.08°F     -40°C to -20°C/-40°F to 14°F 0.9°C/1.62°F • Relative Humidity: 0 to 80% @ 30°C/86°F 4%RH • Measure Accuracy: 80% to 95% @ 30°C/86°F 6%RH • Response Time T63%: 4 minutes at 1 m/s airflow • Data Transmission: Data encryption • Power Options: 2 AAA Alkaline batteries (Zn/Mn02), 2 AAA Lithium batteries (Li/FeS2) • Battery Life @20°C/68°F: Up to 7 years with Alkaline batteries, Up to 10 years with Lithium batteries • Operating Temperature: -20°C to 55°C/-4°F to 131°F with Alkaline batteries, -40°C to 60°C/ -40°F to 140°F with Lithium batteries • Operating Humidity: 0% to 100% non-condensing* • Dimensions: 115x44x25 mm/ 4.5×1.7×1 in • Weight: 65g/ 2.3oz with Alkaline batteries, 57g /2.3ozwith Lithium batteries • Construction ASA Plastic • Protection class IP42 • Compatible base stations • Aranet PRO, Aranet MINI • Marking CE, FCC, IC • Included 2 AAA Alkaline batteries, string NOTE: Sensors are made to be placed vertically (with the ventilation opening facing down) thus being resistive to humidity. * For best accuracy, recommended operating range is 20% to 80% RH (non-condensing) and 5°C to 60°C (41°F to 140°F). Prolonged operation beyond these ranges may result in a shift of sensor reading, with slow recovery time. ** 1, 2, 5, 10 min interval supported from Aranet PRO v1.3.2 and 2, 5, 10 min from Aranet MINI v3.20
    Product Documentation
    TDSPTTU1 Datasheet Learn More »
  2. TDSPT8U1 Aranet Sensor T/RH T: -40°C to 60°CRH: 0% to 100%  IP68 920 MHz

    Aranet Sensor T/RH T: -40°C to 60°CRH: 0% to 100% IP68 920 MHz

    $94.80

    Aranet Sensor T/RH wireless sensor measures temperature and relative humidity. The IP class 68 hermetic enclosure of the sensor ensures that no excessive moisture or dust particles can alter the readings, ensuring constant and reliable data monitoring. The sensor can be placed in harsh environmental conditions and withstand excessive humidity.
    Features
    • Sensors are compatible only with Aranet base stations • Measures: temperature (-40°C to 60°C/ -40°F to 140 °F) • Measures: Relative humidity (0% to 100%) • Line-of-Sight range: up to 3 km/ 1.9mi • Operating environment: indoor and outdoor use • Transmitter power: 14 dBm • Data Transmission: 1, 2, 5, 10 minutes • Battery life: up to 7 years • Protection class: IP68 • Dimensions: 35mmØx120mm/ 1.4inØx4.7in
    Specifications
    • Measurements: Temperature, Relative Humidity • Line of Sight Range: 3km/1.9mi • Operating environment: Indoor and Outdoor use • Transmitter power: 14 dBm • Frequency: Depends on base station instructions • Measurement range:     Temperature: -40°C to 60°C/-40°F to 140°F     Relative Humidity: 0% to 100% • Temperature measurement accuracy:     -10°C to 60°C/14°F to 140°F 0.4°C/0.72°F     -20°C to -10°C/-4°F to 14°F 0.6°C/1.08°F     -40°C to -20°C/-40°F to 14°F 0.9°C/1.62°F • Relative Humidity measurement accuracy     0 to 80% @ 30°C/86°F 4%RH     80% to 95% @ 30°C/86°F 6%RH • Response time Τ63%: 4 minutes at 1 m/s airflow • Data Transmission 1, 2, 5, 10 minutes** • Data Protection Data encryption • Power options:     1 AA Alkaline battery (Zn/Mn02)     1 AA Lithium battery (Li/FeS2) • Battery life @20°C/68°F     Up to 5 years with Alkaline battery     Up to 7 years with Lithium battery • Operating temperature     -20°C to 55°C/-4°F to 131°F with Alkaline battery     -40°C to 60°C/ -40°F to 140°F with Lithium battery • Operating humidity 0% to 100% * • Dimensions: 35mmØx120mm/ 1.4inØx4.7in • Weight:     59g (2.1oz) with Alkaline battery     51g (1.8oz) with Lithium battery • Construction: ASA Plastic • Membrane: GORE • Protection class: IP68 • Marking: CE, FCC • Compatible base stations • Aranet PRO, Aranet MINI • Included: 1 AA Alkaline battery, string
    Product Includes
    (1) T/RH IP68 Sensor (1) 1AA Alkaline Battery (1) Instructions Manual
    Product Documentation
    TDSPT8U1 Datasheet Learn More »
  3. TDSPT0U2.003 Aranet Sensor T-Probe -55°C to 105°C 0.3m cable IP68 920 MHz

    Aranet Sensor T-Probe -55°C to 105°C 0.3m cable IP68 920 MHz

    $130.80

    Aranet Sensor T-Probe -55°C to 105°C 0.3m cable IP68 920 MHz wireless sensor monitors solid surface, liquid and air temperature. The probe can be placed in liquids, or places that require close contact temperature measurements, like heating pipes or soil. Aranet T-probe sensors are hermetically sealed and have IP class 68, which ensures exceptional durability in the harshest conditions.
    Features
    • Measures: temperature (-55°C to 105 °C/ -67°F to +221°F) • Line-of-Sight range: up to 3 km/ 1.9mi • Operating environment: indoor and outdoor use • Transmitter power: 14 dBm • Data Transmission: every 1, 2, 5, 10 minutes • Battery life: up to 7 years • Protection class: IP68 • Dimensions: 35mmØx120mm / 1.4inØx4.7in • Probe length: 0.3m/1m/5m/10m 0.9ft/3.2ft/16.4ft/32.8ft
    Specifications
    • Measurements: Temperature • Line of Sight Range: 3km/1.9 • Operating environment: Indoor and Outdoor use • Transmitter power: 14 dBm • Frequency: Depends on base station instructions • Measurement range: Temperature: -55°C to 105°C/ -67°F to 221°F • Temperature measurement accuracy:     85°C to 105°C/ 185°F to 221°F Up to 2°C/ 3.6°F   &nbps; -10°C to 85°C / 14°F to 185°F Up to 0.5°C/ 0.9°F     -55°C to -10°C/ -67°F to 14°F Up to 2°C/ 3.6°F • Response time Τ63%: 45 seconds at 1 m/s airflow • Data Transmission: 1, 2, 5, 10 minutes** • Data Protection: Data encryption • Power options:     1 AA Alkaline battery (Zn/Mn02)     1 AA Lithium battery (Li/FeS2) • Battery life @20°C/68°F,     Up to 5 years with Alkaline battery &n bsp; 7nbsp; Up to 7 years with Lithium battery • Operating temperature:     -20°C to 55°C/ -4°F to 131°F with Alkaline battery     -40°C to 60°C/ -40°F to 140°F with Lithium battery • Dimensions: 35mmØ x 120mm/ 1.4inØ4.7in • Weight: 88g/3.1oz with Alkaline battery (1m/3.2ft probe) 79g/2.8oz with Lithium battery (1m/3.2ft probe) • Construction: ASA Plastic • Probe length: 0.3m/ 1m/ 5m/ 10m 0.9ft/3.2ft/16.4ft/32.8ft • Compatible base stations: Aranet PRO, Aranet MINI • Protection class: IP68 • Marking: CE, FCC, IC • Included: 1 AA Alkaline battery, string
    Product Includes
    (1) T-Probe Sensor (1) AA Alkaline Battery (1) Instructions Manual
    Product Documentation
    TDSPT0U2.003 datasheet Learn More »
  4. TDSPCLU1.010 Aranet Sensor Current 4 to 20 mA 1m cable IP68 920 MHz

    Aranet Sensor Current 4 to 20 mA 1m cable IP68 920 MHz

    $142.80

    Aranet 4-20mA current sensor is battery-powered and energy-efficient solution designed to integrate with any 3rd party sensor that uses mA as an output. The use cases include monitoring of pH, liquid level, pressure, magnetic flow, velocity, acceleration, industrial vibration and many more.
    Features
    • Sensors are compatible only with Aranet base stations • Measures: current (0-30mA) • Line-of-Sight range: up to 3 km/ 1.9mi • Operating environment: indoor and outdoor use • Transmitter power: 14 dBm • Data Transmission: every 1, 2, 5, 10 minutes • Battery life: up to 7 years • Protection class: IP68 • Dimensions: 35mmØx120mm / 1.4inØx4.7in
    Specifications
    • Measurements 4-20 mA current • Line of Sight Range 3km/1.9 • Operating environment Indoor and Outdoor use • Transmitter power 14 dBm • Frequency Depends on base station instructions • Measurement range 0 – 30 mA • Measurement accuracy ± 0.5 % • Measurement resolution: 0.01 mA • Data Transmission: 1, 2, 5, 10 minutes • Data Protection: Data encryption • Power options: 1 AA Alkaline battery (Zn/Mn02), 1 AA Lithium battery (Li/FeS2) • Battery life @20°C/68°F Up to 5 years with Alkaline battery, Up to 7 years with Lithium battery • Operating temperature -20°C to 55°C/ -4°F to 131°F with Alkaline battery, -40°C to 60°C/ -40°F to 140°F with Lithium battery • Operating humidity: 0% – 100% • Dimensions 35mmØ x 120mm/ 1.4inØ4.7in • Weight: 82g/2.9oz with Alkaline battery (1m/3.2ft probe), 74g/2.6oz with Lithium battery (1m/3.2ft probe) • Construction ASA Plastic • Cable length: 1m/3.2ft • Compatible base stations • Aranet PRO (from sw v1.4) • Protection class: IP68 • Marking CE, FCC • Included: 1 AA Alkaline battery, string NOTE: * For transducers using 4-20 mA as an output, the Aranet PRO web interface user software allows customer to define translation from detected mA values to a user defined measurement unit.
    Product Includes
    (1) Current Sensor (1) AA Alkaline Battery (1) Instructions Manual
    Product Documentation
    TDSPCLU1.010 Datasheet Learn More »
  5. TDSPVMU1.010 Aranet Sensor Voltage -32 to +32 VDC 1m cable IP68 920 MHz

    Aranet Sensor Voltage -32 to +32 VDC 1m cable IP68 920 MHz

    $142.80

    Aranet Voltage sensor is battery-powered and energy-efficient solution designed to integrate with any 3rd party sensor that uses V as an output. The use cases include monitoring of pH, liquid level, pressure, magnetic flow, velocity, acceleration, industrial vibration and many more.
    Features
    • Sensors are compatible only with Aranet base stations • Measures: DC voltage (-32 to +32 VDC) • Line-of-Sight range: up to 3 km/ 1.9mi • Operating environment: indoor and outdoor use • Transmitter power: 14 dBm • Data Transmission: every 1, 2, 5, 10 minutes • Battery life: up to 7 years • Protection class: IP68 • Dimensions: 35mmØx120mm / 1.4inØx4.7in • Probe length: 0.3m/1m/5m/10m 0.9ft/3.2ft/16.4ft/32.8ft
    Specifications
    • Measurements: DC Voltage • Line of Sight Range: 3km/1.9 • Operating environment: Indoor and Outdoor use • Transmitter power: 14 dBm • Frequency: Depends on base station instructions • Measurement range: -32 to +32 VDC • Measurement accuracy: ± 0.5 % • Measurement resolution: 0.01 V • Data Transmission: 1, 2, 5, 10 minutes • Data Protection: Data encryption • Power options 1 AA Alkaline battery (Zn/Mn02), 1 AA Lithium battery (Li/FeS2) Battery life @20°C/68°F     Up to 5 years with Alkaline battery     Up to 7 years with Lithium battery • Operating temperature     -20°C to 55°C/ -4°F to 131°F with Alkaline battery     -40°C to 60°C/ -40°F to 140°F with Lithium battery • Operating humidity: 0% – 100% • Dimensions: 35mmØ x 120mm/ 1.4inØ4.7in • Weight: 82g/2.9oz with Alkaline battery (1m/3.2ft probe) 74g/2.6oz with Lithium battery (1m/3.2ft probe) • Construction: ASA Plastic • Cable length: 1m/3.2ft • Compatible base stations • Aranet PRO (from sw v1.4) • Protection class: IP68 • Marking: CE, FCC • Included: 1 AA Alkaline battery, string NOTE: * For transducers using V (DC) as an output, the Aranet PRO web interface user software allows customer to define translation from detected Voltage values to a user defined measurement unit.
    Product Includes
    (1) Voltage Sensor (1) 1 AA Alkaline Battery (1) Instructions Manual
    Product Documentation
    TDSPVMU1.010 Datasheet Learn More »
  6. TDSPT0U6.010 Aranet Sensor PT100 T: -50°C to 180°C   1m cable IP68 920 MHz

    Aranet Sensor PT100 T: -50°C to 180°C   1m cable IP68 920 MHz

    $214.80

    Aranet PT100 Transmitter is an easy-to-use resistance-to-digital converter optimized for platinum resistance temperature detectors (RTDs). The applications include use for industrial and medical equipment, as well as instrumentation. Wireless transmitter monitors air, liquid, and solid surface temperature. Can be used for 2-wire, 3-wire and 4-wire connections with legacy equipment. A variation Aranet PT100 Sensor is available with 1m temperature probe sensor with a platinum element
    Features
    • Transmitter is compatible only with Aranet base stations • Measures: temperature tested range -200°C (-328°F) up to 800°C (1472°F) • Probe type: Any class PT100 • Line-of-Sight range: up to 3 km/ 1.9mi • Operating environment: indoor and outdoor use • Transmitter power: 14 dBm • Data Transmission: 1, 2, 5, 10 minutes • Battery life: up to 7 years • Protection class: IP68 • Dimensions: 35mmØx120mm / 1.4inØx4.7in
    Transmitter Specifications
    • Measurements: Temperature • Line of Sight Range: 3km/1.9 • Operating environment Indoor and Outdoor use • Transmitter power 14 dBm • Frequency: Depends on base station instructions • Measurement range: Depending on probe type (tested range -200°C (-328°F) up to 800°C (1472°F)) • Probe type: Any class PT100 • Compatible base stations: Aranet PRO, Aranet MINI • Temperature measurement accuracy Transmitter error +/- 0.5°C (0.9°F) + probe error • Data Transmission: 1, 2, 5, 10 minutes** • Data Protection: Data encryption • Power options: 1 AA Alkaline battery (Zn/Mn02), 1 AA Lithium battery (Li/FeS2) • Battery life @20°C/68°F: Up to 5 years @ 1 reading per 10 minutes with Alkaline battery, Up to 7 years @ 1 reading per 10 minutes with Lithium battery • Operating temperature: -20°C (-4°F) to 55°C (131°F) with Alkaline battery, -40°C (-40°F) to 60°C (140°F) with Lithium battery • Dimensions: 35mmØ x 120mm/ 1.4inØ4.7in • Weight: 80g (2.8oz) w Alkaline battery w 1m (3.2ft) cable), 72g (2.5oz) w Lithium battery w 1m (3.2ft) probe) • Construction: ASA Plastic • Probe length: 1m (3.2ft)* • Protection class: IP68 • Marking: CE, FCC • Included: 1 AA Alkaline battery, string NOTE: * Operating temperature of included cable is -40°C to 200°C (-40°F to 392°F) ** 1, 2, 5, 10 min interval supported from Aranet PRO v1.3.2 and 2, 5, 10 min from Aranet MINI v3.20.
    Sensor Specifications
    • Measurements: Temperature • Line of Sight Range: 3km/1.9 • Operating environment: Indoor and Outdoor use • Transmitter power: 14 dBm • Frequency: Depends on base station instructions • Measurement range: Temperature from -50°C (-58°F) up to 180°C (356°F) • Probe type: Class A PT100 • Compatible base stations: Aranet PRO, Aranet MINI • Temperature measurement accuracy: From +/- 0.7°C (1.2F) @0°C (@32°F) to +/- 1.0°C (1.8°F) @180°C (356°F) • Response time Τ63%: 45 seconds at 1 m/s airflow • Data Transmission: 1, 2, 5, 10 minutes** • Data Protection: Data encryption • Power options: 1 AA Alkaline battery (Zn/Mn02), 1 AA Lithium battery (Li/FeS2) • Battery life @20°C/68°F: Up to 5 years @ 1 reading per 10 minutes with Alkaline battery, Up to 7 years @ 1 reading per 10 minutes with Lithium battery • Operating temperature: -20°C (-4°F) to 55°C (131°F) with Alkaline battery, -40°C (-40°F) to 60°C (140°F) with Lithium battery • Dimensions: 35mmØ x 120mm/ 1.4inØ4.7in • Weight: 100g (3.5oz) w Alkaline battery w 1m(3.2ft) cable w PT100 probe) 92g (3.2oz) w Lithium battery w 1m (3.2ft) cable w PT100 probe) • Construction: ASA Plastic • Probe length: 1 m (3.2ft) • Protection class: IP68 • Marking: CE, FCC • Included: 1 AA Alkaline battery, string NOTE: ** 1, 2, 5, 10 min interval supported from Aranet PRO v1.3.2 and 2, 5, 10 min from Aranet MINI v3.20.
    Product Includes
    (1) PT100 Sensor (1) 1 AA Alkaline Battery (1) Instructions Manual
    Product Documentation
    TDSPT0U6.010 Datasheet Learn More »
  7. TDSPTEU6.010 Aranet Sensor PT100 T: -190°C to 260°C   1m cable IP68 920 MHz

    Aranet Sensor PT100 T: -190°C to 260°C   1m cable IP68 920 MHz

    $238.80

    Aranet PT100 EXT sensors measure and monitor air, liquid and solid surface temperature. The probe can be placed in liquids or places that require close contact temperature measurements, like heating pipes or soil. Use cases include air conditioning and ventilation systems (HVAC), food industry, chemical and medicine laboratory, bio-engineering.
    Features
    • Sensors are compatible only with Aranet base stations • Measures: temperature -190°C to 260°C (-310°F to 500°F) • Line-of-Sight range: up to 3 km/ 1.9mi • Operating environment: indoor and outdoor use • Transmitter power: 14 dBm • Data Transmission: every 1, 2, 5, 10 minutes • Battery life: up to 7 years • Protection class: IP65 • Dimensions: 35mmØx120mm / 1.4inØx4.7in
    Specifications
    • Measurements: Temperature • Line of Sight Range: 3km/1.9 • Operating environment Indoor and Outdoor use • Transmitter power 14 dBm • Frequency: Depends on base station instructions • Measurement range:     Temperature: -190°C to 260°C (-310°F to 500°F) • Temperature measurement accuracy:     +/- 1.0°C (1.8F) @ -190°C (@-310°F) Up to 2°C/ 3.6°F     +/- 0.7°C (1.2F) @ 0°C (@32°F) Up to 0.5°C/ 0.9°F     +/- 1.2°C (2.1°F) @ 260°C (500°F) Up to 2°C/ 3.6°F • Response time Τ63%: 45 seconds at 1 m/s airflow • Data Transmission: 1, 2, 5, 10 minutes • Data Protection: Data encryption • Power options"     1 AA Alkaline battery (Zn/Mn02)     1 AA Lithium battery (Li/FeS2) • Battery life @20°C/68°F     Up to 5 years with Alkaline battery     Up to 7 years with Lithium battery • Operating temperature     -20°C to 55°C/ -4°F to 131°F with Alkaline battery     -40°C to 60°C/ -40°F to 140°F with Lithium battery • Dimensions: 35mmØ x 120mm/ 1.4inØ4.7in • Weight: 100g/3.5oz with Alkaline battery (1m/3.2ft probe) 92g/3.2oz with Lithium battery (1m/3.2ft probe) • Construction: ASA Plastic Sensor, PTFE probe cable • Probe length: 1m/3.2ft • Probe type: Class A PT100 • Compatible base stations: Aranet PRO (from sw v1.4) • Protection class IP65 • Marking: CE, FCC • Included: 1 AA Alkaline battery, string ** 1, 2, 5, 10 min interval supported from Aranet PRO v1.3.2 and 2, 5, 10 min from Aranet MINI v3.20.
    Product Includes
    (1) PT100 EXT sensor (1) AA Alkaline Battery (1) Instructions Manual
    Datasheet
    TDSPTEU6.010 Learn More »
  8. TDSPSVU1.050 Aranet Sensor Weight 0 to 50 kg 1m cable IP67 920 MHz

    Aranet Sensor Weight 0 to 50 kg 1m cable IP67 920 MHz

    $282.00

    Aranet Plant weight is essential to quantify plant growth and increase in biomass. The weight sensor allows close monitoring of plant growth and development, therefore allowing for more precise optimization of plant environmental conditions. The wireless weight sensor is also applicable in warehouses, food manufacturing industry and transport.
    Features
    • The sensor is compatible only with Aranet base stations • Measures: weight (0-50 kg, 0-100 kg) • Line-of-Sight range: up to 3 km/ 1.9mi • Operating environment: indoor and outdoor use • Transmitter power: 14 dBm • Data Transmission: 1,2, 5, 10 minutes • Battery life: up to 7 years • Protection class: IP67 • Cable length: 0.2m (0.65ft)
    Specifications
    • Measurements: Weight • Line of Sight Range: 3km/1.9 • Operating environment Indoor and Outdoor use • Transmitter power 14 dBm • Frequency: Depends on base station instructions • Measurement range: 0-50 kg, 0-100 kg * • Measurement accuracy ± 0.02% FS (C3 Class Load Cell) • Measurement resolution: 1g • Safe overload: 150% • Ultimate overload: 300% • Data transmission: 1, 2, 5, 10 minutes • Data protection: Data encryption • Power options: 1 AA Alkaline battery (Zn/Mn02), 1 AA Lithium battery (Li/FeS2) • Alkaline Battery life @20°C / 68°F: Up to 5 years • Lithium Battery life @20°C / 68°F Up to 7 years • Operating temperature w Alkaline -20°C to 55°C (-4°F to 131°F) • Operating temperature w Lithium: -35°C to 60°C (-31°F to 140°F) • Operating humidity: 0% to 100% • Dimensions: 35mmØx120mm (1.4”Øx4.7) Sensor body &nbps;   51mm x 150mm x 15mm (2.0” x 5.9” x 0.6”) 50 kg Load Cell w hooks &nbps;   51mm x 167mm x 21mm (2.0” x 6.6” x 0.8”) 100 kg Load Cell w hooks • Weight: 424g (15.0oz) w 50 kg Load Cell w Alkaline battery &nbps;   416g (14.7oz) w 50 kg Load Cell w Lithium battery &nbps;   595g (21.0oz) w 100 kg Load Cell w Alkaline battery &nbps;   587g (20.7oz) w 100 kg Load Cell w Lithium battery • Construction ASA Plastic (Sensor body), Alloy steel (Load Cell) • Protection class: IP67 • CE/FCC/IC marking: CE, FCC • Included: 1 AA Alkaline battery, string • Cable length 0.2m (0.65ft) • Compatible base stations: Aranet PRO (from sw v1.4) * Other weight options available on request
    Product Includes
    (1) Weight Sensor (1) AA Alkaline Battery (1) User Instructions
    Datasheet
    TDSPSVU1.050 Learn More »