TDSPTTU1 Aranet Sensor T/RH T: -40°C to 60°CRH: 0% to 100%  IP42 920 MHz

Aranet Sensor T/RH T: -40°C to 60°CRH: 0% to 100% IP42 920 MHz

Aranet Sensor T/RH T: -40°C to 60°CRH: 0% to 100% IP42 920 MHz

SKU
TDSPTTU1
Availability: In stock - Direct ship from Colorado.
Aranet wireless temperature and relative humidity sensors have exceptionally low energy consumption that allows the sensors to function up to 10 years without replacing the battery.
$96.00
Aranet wireless temperature and relative humidity sensors have exceptionally low energy consumption that allows the sensors to function up to 10 years without replacing the battery. Aranet Sensors are extremely durable and can be placed in an open environment as well as indoors or humid locations.

Features
• Sensors are compatible only with Aranet base stations
• Measures: temperature (-40°C to 60°C/ -40°F to 140 °F)
• Measures: Relative humidity (0% to 100%)
• Line-of-Sight range: up to 3 km/ 1.9mi
• Operating environment: indoor and outdoor use
• Transmitter power: 14 dBm
• Data Transmission: 1, 2, 5, 10 minutes
• Battery life: up to 10 years
• Protection class: IP42
• Dimensions: 115x44x25 mm/ 4.5×1.7×1 in

Specifications
• Measurements: Temperature and Relative Humidity
• Line if Sight Range: 3km/1.9mi
• Operating Environment: Indoor and Outdoor use
• Transmit power: 14dBm
• Frequency: Depends on base station instructions
• Measurement Range:
    Temperature: -40°C to 60°C/-40°F to 140°F
    Relative Humidity: 0% to 100%
• Temperature Measurement Accuracy:
    -10°C to 60°C/14°F to 140°F 0.4°C/0.72°F
    -20°C to -10°C/-4°F to 14°F 0.6°C/1.08°F
    -40°C to -20°C/-40°F to 14°F 0.9°C/1.62°F
• Relative Humidity: 0 to 80% @ 30°C/86°F 4%RH
• Measure Accuracy: 80% to 95% @ 30°C/86°F 6%RH
• Response Time T63%: 4 minutes at 1 m/s airflow
• Data Transmission: Data encryption
• Power Options: 2 AAA Alkaline batteries (Zn/Mn02), 2 AAA Lithium batteries (Li/FeS2)
• Battery Life @20°C/68°F: Up to 7 years with Alkaline batteries, Up to 10 years with Lithium batteries
• Operating Temperature: -20°C to 55°C/-4°F to 131°F with Alkaline batteries, -40°C to 60°C/ -40°F to 140°F with Lithium batteries
• Operating Humidity: 0% to 100% non-condensing*
• Dimensions: 115x44x25 mm/ 4.5×1.7×1 in
• Weight: 65g/ 2.3oz with Alkaline batteries, 57g /2.3ozwith Lithium batteries
• Construction ASA Plastic
• Protection class IP42
• Compatible base stations
• Aranet PRO, Aranet MINI
• Marking CE, FCC, IC
• Included 2 AAA Alkaline batteries, string

NOTE: Sensors are made to be placed vertically (with the ventilation opening facing down) thus being resistive to humidity.
* For best accuracy, recommended operating range is 20% to 80% RH (non-condensing) and 5°C to 60°C (41°F to 140°F).
Prolonged operation beyond these ranges may result in a shift of sensor reading, with slow recovery time.
** 1, 2, 5, 10 min interval supported from Aranet PRO v1.3.2 and 2, 5, 10 min from Aranet MINI v3.20

Product Documentation
TDSPTTU1 Datasheet
More Information
SKU TDSPTTU1
Manufacturer Aranet
Country of Manufacture Latvia
Large or Oversize Package No
HTS Code 8517.69.0000
ECCN EAR99
UPC 752830770256